Hemodialysis

Evaluation of Circulating Glypican-4 in Patients with ESKD

Kidney360Published Cohort study

Authors' conclusion

GPC4 levels were markedly elevated in patients initiating dialysis and were linked with several pathophysiologic characteristics commonly observed in ESKD. However, our findings did not indicate that elevated serum GPC4 levels serve as a significant predictor of all-cause mortality in this patient population.

Study context

Population
Patients starting chronic dialysis (ESKD) and sex- and age-matched controls
Participants
187 vs 108
Exposure
Incident dialysis patients vs controls without evidence of kidney disease
  • Incident dialysisn = 187
  • Controlsn = 108reference
Outcome
Serum GPC4 levels
Follow-up
Before initiation of dialysis
Methodological detailssex- and age-matched controls, Serum GPC4 measured by enzyme-linked immunosorbent assay
  • Sex- and age-matched controls
  • Serum GPC4 measured by enzyme-linked immunosorbent assay

Main finding

As reported in the abstract

  • Serum GPC4 approximately ten-fold higher in incident dialysis patients vs controls, with excellent classification ability to distinguish the two groups

Observational data: associations, not effects.

Further findings

Correlates of GPC4 in incident dialysis patients

Significant positive correlation with creatinine and phosphate
Significant negative correlation with eGFR, hemoglobin, erythrocytes, calcium and cholinesterase

All-cause mortality · median follow-up 3.8 years

No significant association between GPC4 levels and all-cause mortality in patients starting dialysis

Original publication

Evaluation of Circulating Glypican-4 in Patients with ESKD. Kidney360. Published 10 March 2025. doi:10.34067/kid.0000000744

Composed by AI from the published abstract and checked against it. How Briefs are made →