Expanded Hemodialysis with Theranova Dialyzer and Residual Kidney Function in Patients Starting Long-Term Hemodialysis: A Randomized Controlled Trial
Primary result · Change in GFRResult — go to the resultLeast squares mean difference of change −1.4 ml/min per 1.73 m² 95% CI −2.4 to −0.5Authors' conclusion
This trial suggests that expanded hemodialysis using the Theranova dialyzer slowed decline in residual kidney function compared with a high-flux dialyzer in patients starting treatment with long-term hemodialysis.
Study context
- Population
- Patients initiating long-term HD
- Participants
- 80 patients
- Comparison
- Theranova 400 (expanded HD) vs high-flux dialyzer with similar surface area over 12 months
- Primary endpoint
- Change in GFR (mean of urea and creatinine clearance)
- Follow-up
- 12 months
Primary result
Change in GFR
Least squares mean difference of change
−1.4 ml/min per 1.73 m²
95% CI −2.4 to −0.5
Theranovavs High-flux
least squares mean difference of change −1.4 ml/min per 1.73 m² (95% CI −2.4 to −0.5)
As reported in the abstract
Key notes
- Significantly smaller decrease in GFR with Theranova
Secondary outcomes
24-hour urine volume
- Theranova maintained greater 24-hour urine volume until 9 months, not at 12 months, vs high-flux
Middle molecules and inflammatory cytokines
- Higher reduction ratio for κ/λ free light chains, TNF-α and growth differentiation factor-15 with Theranova than high-flux
Kidney injury marker IGF-binding protein 7
- Increase in IGF-binding protein 7 attenuated with Theranova
Hospitalization rate and mortality
- Hospitalization rate and mortality did not differ between the two groups
Original publication
Expanded Hemodialysis with Theranova Dialyzer and Residual Kidney Function in Patients Starting Long-Term Hemodialysis: A Randomized Controlled Trial. J Am Soc Nephrol. Published 4 March 2025. doi:10. 1681/ asn. 0000000655
Composed by AI from the published abstract and checked against it. How Briefs are made →