Efficacy and Safety of a Low-Flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Failure, a Pilot Study in China
Authors' conclusion
Our clinical series indicated that LF-ECCO2R seemed to be safely applied in patients with acute respiratory failure. The efficacy of CO2 removal as well as the improved respiratory parameters was also observed. However, large-scale randomized clinical trials are needed to confirm the effects.
Study context
- Population
- Adults with acute respiratory failure commenced on LF-ECCO2R in a Chinese tertiary regional intensive care unit (ICU), June 2020 to September 2021
- Participants
- 12 adults
- Outcome
- Safety and efficacy of LF-ECCO2R
Methodological detailsretrospective case note review, single-centre, pilot study
- Retrospective case note review
- Single-centre
- Pilot study
Main finding
As reported in the abstract
Efficacy: ventilation parameters and arterial blood gases
- Statistically significant reduction in respiratory rate, driving pressure, PaCO2 and blood lactate
- Statistically significant improvement in pH and PaO2/FiO2
Further findings
- Discharged alive from ICU
- 6 out of 12 patients (50%)
Safety
| Outcome | Values |
|---|---|
| Complications related to LF-ECCO2R | LF-ECCO2R 3 events |
Complications related to LF-ECCO2R
- None resulting in serious adverse outcomes
Original publication
Efficacy and Safety of a Low-Flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Failure, a Pilot Study in China. Blood Purif. Published 27 July 2022. doi:10. 1159/ 000525867