Contrast-enhanced ultrasonography reveals a lower cortical perfusion and a decreased renal flow reserve in hypertensive patients
Authors' conclusion
HT patients had a lower basal renal cortical perfusion. During the cold pressor test, HT participants had a smaller increase in the PI, suggesting that renal cortical flow reserve is impaired.
Study context
- Population
- Normotensive and hypertensive participants with normal kidney function
- Participants
- 73 participants
- Exposure
- Hypertensive (HT) vs normotensive (NT) participants
- HTn = 32
- Outcome
- Renal perfusion index (PI) by contrast-enhanced ultrasonography (CEUS) at rest and during a 2-min cold pressor test
Methodological detailscontrast-enhanced ultrasonography, cold pressor test, linear mixed model analysis
- Contrast-enhanced ultrasonography
- Cold pressor test
- Linear mixed model analysis
Main finding
As reported in the abstract
Baseline renal PI
P < 0.001
Key notes
- Lower with HT
Observational data: associations, not effects.
Further findings
| Outcome | HT | NT | P value |
|---|---|---|---|
| Increase in PI during CPTIncrease blunted in HT | median +504 (IQR 117–920) a.u. | median +1159 (IQR 678–2352) a.u | interaction P = .013 |
Systemic response to cold pressor test (CPT)
- CPT increased BP, heart rate and catecholamines in all participants
Modifiers
- Age, sex and BMI did not modify these results
Original publication
Contrast-enhanced ultrasonography reveals a lower cortical perfusion and a decreased renal flow reserve in hypertensive patients. Nephrol Dial Transplant. Published 8 August 2023. doi:10. 1093/ ndt/ gfad158
Composed by AI from the published abstract and checked against it. How Briefs are made →