Kidney & hypertension

Assessment of renal artery stenosis using renal fractional flow reserve and correlation with angiography and color Doppler ultrasonography: data from FAIR-pilot trial

Hypertens ResPublished Diagnostic accuracy study

Study context

Population
Patients with at least unilateral renal artery stenosis (RAS) in the FAIR-pilot study
Participants
58 patients77 renal artery lesions
Comparison
Color Doppler ultrasonography (CDU) parameters and angiography vs renal fractional flow reserve
Outcome
Correlation of CDU and angiography with rFFR, and cut-off points of US parameters for significant RAS (rFFR<0.8)
Methodological detailsdata from FAIR-pilot trial, renal fractional flow reserve (rFFR) measured by pressure wire after dopamine-induced renal hyperemia
  • Data from FAIR-pilot trial
  • rFFR measured by pressure wire after dopamine-induced renal hyperemia

Performance

As reported in the abstract

Detection of significant RAS (rFFR<0.8) by CDU parameters
Test or modelRho with rFFRPCut-offSensitivitySpecificityAccuracyAUC
Peak systolic velocityPSV−0.668P < 0.00012.415 m/s90%75%81%0.84
Renal-to-aortic ratioRAR−0.597P < 0.0014.495— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract
Resistive indexRI— not stated in the abstract— not stated in the abstract0.605— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract
ΔRI— not stated in the abstract— not stated in the abstract0.04— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract

Rho with rFFR

Peak systolic velocityPSV−0.668
Renal-to-aortic ratioRAR−0.597
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

P

Peak systolic velocityPSVP < 0.0001
Renal-to-aortic ratioRARP < 0.001
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

Cut-off

Peak systolic velocityPSV2.415 m/s
Renal-to-aortic ratioRAR4.495
Resistive indexRI0.605
ΔRI0.04

Sensitivity

Peak systolic velocityPSV90%
Renal-to-aortic ratioRAR— not stated in the abstract
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

Specificity

Peak systolic velocityPSV75%
Renal-to-aortic ratioRAR— not stated in the abstract
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

Accuracy

Peak systolic velocityPSV81%
Renal-to-aortic ratioRAR— not stated in the abstract
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

AUC

Peak systolic velocityPSV0.84
Renal-to-aortic ratioRAR— not stated in the abstract
Resistive indexRI— not stated in the abstract
ΔRI— not stated in the abstract

Original publication

Assessment of renal artery stenosis using renal fractional flow reserve and correlation with angiography and color Doppler ultrasonography: data from FAIR-pilot trial. Hypertens Res. Published 21 October 2024. doi:10.1038/s41440-024-01948-5

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.