Hemodialysis

Comparison of Residual Kidney Function Assessment Between the Hemodialysis 2-Day and 3-Day Interdialytic Interval

Kidney360Published Prospective cohort study

Authors' conclusion

There was no statistically significant difference observed in assessed RKF between the LIDP and SIDP. Measured RKF through samples collected from the LIDP and SIDP is comparable.

Study context

Population
Clinically stable, ambulatory facility HD patients
Participants
34 participants
Exposure
Long vs short interdialytic interval
Outcome
Measured residual kidney function (mean of urinary urea and creatinine clearances)
Methodological detailspaired comparison within patients
  • Paired comparison within patients

Main finding

As reported in the abstract

Assessed residual kidney function
GroupValueMedian [range as printed]
LIDPmean 8 ± 6 ml/min6.3 [3.2-10.4]
SIDPmean 6 ± 4 ml/min5.8 [3.8-8.9]

Value

LIDPmean 8 ± 6 ml/min
SIDPmean 6 ± 4 ml/min

Median [range as printed]

LIDP6.3 [3.2-10.4]
SIDP5.8 [3.8-8.9]
  • LIDP vs SIDP: P = 0.24 — no significant difference
  • LIDP vs SIDP: P = 0.13 — no significant difference

Observational data: associations, not effects.

Further findings

Serum creatinine · higher in LIDP

P = <0.01

Urine creatinine · no statistically significant difference

P = 0.06

Serum urea · higher in LIDP

P = 0.01

Urine urea · no statistically significant difference

P = 0.87

Urine volume · no statistically significant difference

P = 0.06

Original publication

Comparison of Residual Kidney Function Assessment Between the Hemodialysis 2-Day and 3-Day Interdialytic Interval. Kidney360. Published 8 June 2023. doi:10.34067/kid.0000000000000174

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.