Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management
Authors' conclusion
We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP/PWC trends. We further establish that physiological BP/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.
Study context
- Population
- HD patients in a quality improvement project involving targeted fluid management120 visits (77/43 at baseline/follow-up)
- Participants
- 80 patients
- Comparison
- Intra-patient association of post-dialysis fluid overload (FO) with interdialytic blood pressure (BP)/pulse wave characteristics (PWCs)
Methodological detailsobservational, longitudinal, targeted fluid management, bioimpedance-derived FO, interdialytic 44-h ambulatory BP/PWC monitoring, trended cosinor linear mixed-effects models
- Observational, longitudinal
- Targeted fluid management
- Bioimpedance-derived FO
- Interdialytic 44-h ambulatory BP/PWC monitoring
- Trended cosinor linear mixed-effects models
Primary result
As reported in the abstract
Interdialytic BP/PWCs per 1 L increase in post-dialysis FO at the patient level
- Peripheral systolic BP
- 4.54 mmHg, P < 0.001
- Peripheral diastolic BP
- 2.55 mmHg, P < 0.001
- Peripheral resistance
- 0.03 s*mmHg/mL, P = 0.011
- Augmentation index
- 1.38%, P = 0.007
- Forward wave amplitude
- 0.56 mmHg, P = 0.025
- Backward wave amplitude
- 0.61 mmHg, P = 0.027
- Reservoir pressure peak
- 3.83 mmHg, P < 0.001
- Pulse wave velocity
- 0.12 m/s, P = 0.007
Key notes
- All increased with higher FO
Further findings
Post-dialysis FO in baseline hypervolemic patients · baseline to follow-up
- Baseline
- 2.7 ± 1.3 L
- Follow-up
- 0.9 ± 1.7 L
Interdialytic slopes
- Higher FO associated with decreased interdialytic slopes of all BPs, peripheral resistance, backward wave amplitude, reservoir peak pressure and pulse wave velocity
Circadian rhythms
- FO interacted with circadian rhythms of stroke volume, peripheral resistance, forward wave amplitude and excess pressure peak
Original publication
Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management. Clin Kidney J. Published 12 August 2026. doi:10. 1093/ ckj/ sfag273
Composed by AI from the published abstract and checked against it. How Briefs are made →