Catheter‐Related Infection in Uncuffed, Non‐Tunneled Dual‐Lumen Catheters: Incidence and Risk Factors by Internal Jugular Versus Femoral Site in a Retrospective Cohort
Authors' conclusion
For uncuffed, non-tunneled dual-lumen catheters used for dialysis vascular access, the jugular insertion site does not demonstrate a reduced risk of CRBSI compared to the femoral site. However, jugular catheter placement is associated with a longer dwelling time and a lower mortality rate.
Study context
- Population
- Patients with uncuffed, non-tunneled dual-lumen catheters for kidney replacement therapy (KRT)
- Participants
- 572 patients
- Exposure
- Internal jugular vs femoral insertion site of uncuffed, non-tunneled dual-lumen catheters
- Jugularn = 286
- Femoraln = 286reference
- Outcome
- CRBSI incidence
Methodological detailsregression analyses of CRBSI risk factors
- Regression analyses of CRBSI risk factors
Main finding
As reported in the abstract
CRBSI incidence proportion
P = 1.0
Observational data: associations, not effects.
Further findings
CRBSI incidence rate
P = 0.154
Catheter dwelling time · significantly longer with jugular
P < 0.001
| Outcome | Jugular | Femoral | P value |
|---|---|---|---|
| 30-day incidence proportion of deathSignificantly lower with jugular | 0.105 | 0.608 | P < 0.001 |
CRBSI risk factors
- Pre-existing cerebrovascular disease and congestive HF were significant risk factors for CRBSI
Original publication
Catheter‐Related Infection in Uncuffed, Non‐Tunneled Dual‐Lumen Catheters: Incidence and Risk Factors by Internal Jugular Versus Femoral Site in a Retrospective Cohort. Hemodial Int. Published 21 May 2025. doi:10. 1111/ hdi. 13261
Composed by AI from the published abstract and checked against it. How Briefs are made →