Chronic kidney disease

Accuracy of Shorter Iohexol GFR Measurement Protocols in Individuals with Preserved Kidney Function

Kidney360Published Diagnostic accuracy study

Authors' conclusion

These results demonstrate that shortening the mGFR procedure in individuals with preserved GFR provides similar results to the current standard while significantly decreasing procedure time.

Study context

Population
Individuals with preserved GFR
Participants
43 individuals
Comparison
Shorter iohexol multisample protocols vs reference Measured GFR (mGFR)
Outcome
Performance vs R-mGFR: bias, precision and accuracy (P2, P5, mean absolute error)

Performance

As reported in the abstract

Performance of shorter mGFRs vs R-mGFR
Test or modelValueBiasMean absolute error
Reference mGFRR-mGFRmean 102.3 ± 13.7 ml/min per 1.73 m²— not stated in the abstract— not stated in the abstract
Shorter mGFRs— not stated in the abstract<1 ml/min per 1.73 m²<1.6 ml/min per 1.73 m²

Value

Reference mGFRR-mGFRmean 102.3 ± 13.7 ml/min per 1.73 m²
Shorter mGFRs— not stated in the abstract

Bias

Reference mGFRR-mGFR— not stated in the abstract
Shorter mGFRs<1 ml/min per 1.73 m²

Mean absolute error

Reference mGFRR-mGFR— not stated in the abstract
Shorter mGFRs<1.6 ml/min per 1.73 m²

Original publication

Accuracy of Shorter Iohexol GFR Measurement Protocols in Individuals with Preserved Kidney Function. Kidney360. Published 15 July 2024. doi:10.34067/kid.0000000000000511

Composed by AI from the published abstract and checked against it. How Briefs are made →