Accuracy of GFR Estimating Equations in Patients with Discordances between Creatinine and Cystatin C-Based Estimations
Authors' conclusion
When eGFR cr and eGFR cys are highly discordant in clinical practice, eGFR cr-cys is more accurate than either eGFR cr or eGFR cys .
Study context
- Population
- Adults referred for measured GFR (mGFR) using plasma clearance of iohexol in Stockholm, Sweden9,404 concurrent measurements
- Participants
- 6,185 adults
- Comparison
- eGFRcr vs eGFRcys vs eGFRcr-cys against mGFR
- Outcome
- Performance against mGFR: median bias, P30 and correct classification of GFR categories
Methodological detailsreal-world, Stockholm, Sweden, stratified by discordance between eGFRcys and eGFRcr
- Real-world
- Stockholm, Sweden
- Stratified by discordance between eGFRcys and eGFRcr
Performance
As reported in the abstract
Performance vs mGFR when eGFR cys <eGFR cr (eGFR cys at least 20% lower than eGFR cr)
Performance vs mGFR when eGFR cys <eGFR cr (eGFR cys at least 20% lower than eGFR cr) eGFR cr median bias 15.0 ml/min per 1.73 m² · eGFR cys median bias −8.5 ml/min per 1.73 m² · eGFR cr-cys median bias 0.8 ml/min per 1.73 m²
P30
Correct classification
Key notes
- eGFR cr-cys much more accurate in cases of discordance
- 47% of samples
More notes
- eGFR cr overestimation; eGFR cys underestimation
Further findings
Median bias, ml/min per 1.73m 2
| Outcome | eGFR cr | eGFR cys | eGFR cr-cys |
|---|---|---|---|
| Median bias vs mGFR when eGFR cys >eGFR cr (eGFR cys at least 20% higher than eGFR cr) | −4.5 | 8.4 | 1.4 |
- Median bias vs mGFR when eGFR cys >eGFR cr (eGFR cys at least 20% higher than eGFR cr): 8% of samples
Performance when eGFR cys ≈eGFR cr (within 20%)
- All three estimating equations performed similarly
- 4226 (45%) samples
Subgroups
- Findings consistent among individuals with CVD, HF, diabetes mellitus, liver disease, and cancer