Acute kidney injury

Bioimpedance-Guided Fluid Removal in Continuous KRT: The VENUS Randomized Clinical Trial

Clin J Am Soc NephrolPublished Randomised controlled trial

Authors' conclusion

BIA-guided volume management did not affect the proportion of reaching the e-euvolemia at 7 days of the start of CKRT.

Study context

Population
Patients with AKI requiring continuous KRT (CKRT) whose weight at CKRT start had increased by ≥5% vs admission or with total body water (TBW)/H2 ≥13 L/m²
Participants
208 patients
Comparison
Bioimpedance analysis (BIA)-guided fluid management vs conventional fluid management
  • Interventionn = 105
  • Controln = 103reference
Primary endpoint
Proportion attaining e-euvolemia (TBW/H2 D7 minus D0 <−2.1 L/m², or TBW/H2 on D7 <13 L/m²)
Follow-up
7 days postrandomization
Methodological detailsmulticenter
  • Multicenter

Primary result

As reported in the abstract

E-euvolemia · 7 days

P = 0.50

Secondary outcomes

TBW/H2 on D7

E-euvolemia · D1 · significantly higher with Intervention

P = 0.02

L/m²

OutcomeInterventionControlP value
Change in TBW/H2, D7 vs D0−1.13−1.08P = 0.84

Safety

Adverse events did not differ significantly between the groups

Original publication

Bioimpedance-Guided Fluid Removal in Continuous KRT: The VENUS Randomized Clinical Trial. Clin J Am Soc Nephrol. Published 12 September 2024. doi:10.2215/cjn.0000000000000557