Use of Analog and Human Insulin in a European Hemodialysis Cohort With Type 2 Diabetes: Associations With Mortality, Hospitalization, Major Adverse Cardiovascular Events (MACE), and Hypoglycemia
Main finding · All-cause mortalityResult — go to the resultAdjusted hazard ratio 0.808 95% CI 0.66–0.99Authors' conclusion
In this large multinational cohort of people with type 2 diabetes and kidney failure receiving maintenance hemodialysis, treatment with analog insulins was associated with better clinical outcomes when compared with human insulin.
Study context
- Population
- People with type 2 diabetes treated with insulin and KF commencing HD, 2007–2009, 7 European countries; type 1 diabetes excluded
- Participants
- 1,446 people7 European countries
- Exposure
- Analog insulin vs human insulin
- Analog insulinn = 713
- Human insulinn = 733reference
- Outcome
- All-cause mortality, MACE, all-cause hospitalization and confirmed hypoglycemia (blood glucose <3.0 mmol/L during HD)
- Follow-up
- 3 years
Methodological detailsAROii study, 288 dialysis facilities, 7 European countries, inverse probability weighted Cox proportional hazards models, sensitivity analyses
- AROii study
- 288 dialysis facilities, 7 European countries
- Inverse probability weighted Cox proportional hazards models
- Sensitivity analyses
Main finding
All-cause mortality
Analog insulinvs Human insulin
aHR 0.808 (95% CI 0.66–0.99); P = 0.04
As reported in the abstract
Key notes
- Consistent across sensitivity analyses
Observational data: associations, not effects.
Further findings
3 years
| Outcome | Analog insulin | Human insulin | aHR (95% CI) | P value | |
|---|---|---|---|---|---|
| MACE | 26.8% | 35.9% | 0.817 (0.68–0.98) | P = 0.03 | |
| All-cause hospitalization | 58.2% | 75.0% | 0.757 (0.67–0.86) | P < 0.001 | |
| 0.512Adjusted hazard ratio (log scale) |
Safety
| Outcome | Analog insulin | Human insulin | aHR (95% CI) | P value | |
|---|---|---|---|---|---|
| Confirmed hypoglycemia · 3 yearsComparable between insulin types | 14.1% | 15.0% | 1.169 (0.80–1.72) | P = 0.4 | |
| 0.512Adjusted hazard ratio (log scale) |
Original publication
Use of Analog and Human Insulin in a European Hemodialysis Cohort With Type 2 Diabetes: Associations With Mortality, Hospitalization, MACE, and Hypoglycemia. Am J Kidney Dis. Published 30 August 2023. doi:10. 1053/ j. ajkd. 2023. 05. 010
Composed by AI from the published abstract and checked against it. How Briefs are made →