Ultrafiltration Patterns during Automated Peritoneal Dialysis: Findings and Insights to Peritoneal Physiology
Authors' conclusion
We observed a consistent increase in UF volumes achieved per cycle over the course of an APD treatment session with numerous clinical and physiologic implications. This provides the foundation for future studies investigating peritoneal intercycle variations and membrane physiology.
Study context
- Population
- Adult patients on automated peritoneal dialysis (APD) for ≥3 months, on peritoneal dialysis (PD) for ≥3 months, without peritonitis within 3 months7 consecutive APD sessions each
- Participants
- 39 patients
- Outcome
- UF achieved during each cycle of an APD treatment session
Methodological detailssingle-center
- Single-center
Main finding
As reported in the abstract
UF per cycle over an APD session
Probability of positive ultrafiltration (UF), cycle 1
48.9%
Probability of positive UF, cycle 6
90.5%
First cycle UF volume vs a middle cycle, P < 0.001
−230 ml
Last cycle UF volume vs a middle cycle, P < 0.001
277 ml
Key notes
- Cycles 2-6 achieved progressively higher UF volumes than cycle 1 (adjusted), P < 0.001
- Adjusted for average dextrose concentration, dwell time, fill volume, solute transfer rate, and number of cycles
Original publication
Ultrafiltration Patterns during Automated Peritoneal Dialysis: Findings and Insights to Peritoneal Physiology. Kidney360. Published 8 July 2024. doi:10. 34067/ kid. 0000000000000506