Hemodialysis

Ulnar–Basilic Arteriovenous Fistula for Hemodialysis: A 15‐Year Overview

Semin DialPublished Retrospective case series

Authors' conclusion

While the difficulties experienced in achieving functional UBFs for HD are highlighted in this long-term perspective, its safety and durability make it a viable option in managing an increasingly comorbid patient population.

Study context

Population
Patients receiving hemodialysis (HD) with ulnar-basilic fistulas (UBFs) created between 2008 and 202311 UBFs created
Participants
253 patients
Outcome
UBF creation and functionality
Methodological detailsretrospective review, 2008–2023
  • Retrospective review
  • 2008–2023

Main finding

As reported in the abstract

Patients receiving HD with an AVF

82.2%

UBFs among the 150 distal arteriovenous fistulas (AVFs) functional for HD

3.3%

n = 5

UBF fistulas created

11

Patients with an immediate thrill

9

Further findings

Characteristics of UBF failure

Aged > 85 years
3
Concurrent diabetes mellitus, peripheral vascular disease and ischemic heart disease
3

Survival in the UBF group

Survival correlated with duration of dialysis in the patients for whom the UBF was the sole AVF
3
Patient achieving a prolonged period of > 10 years
1

Safety

No incidences of ischemia, hand edema or ulnar nerve lesions

Original publication

Ulnar–Basilic Arteriovenous Fistula for Hemodialysis: A 15‐Year Overview. Semin Dial. Published 5 December 2024. doi:10.1111/sdi.13231

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.