Transforming the Venous Blood Gas to the Arterial Blood Gas from Concurrent Measurements
Authors' conclusion
The results of this transformation meet acceptable clinical expectations and are supported by the large database used to generate the formulas that estimate independently the three ABG components (pCO 2 , pH, and HCO 3- ).
Study context
- Population
- Concurrently collected arterial and venous blood gas samples5,419 samples
- Comparison
- Estimated arterial values from venous blood gas (VBG) vs measured arterial blood gas (ABG)
- Outcome
- Agreement of arterial pCO2, pH and HCO3- estimated from VBG with measured arterial values
Methodological detailslinear regression, concurrent arterial and venous samples
- Linear regression
- Concurrent arterial and venous samples
Main finding
As reported in the abstract
Estimated vs measured arterial values
- pCO2: venous–arterial correlation r
- 0.93 (P < 0.0001)
- pCO2: median difference estimated vs measured
- 0.02 mm Hg; 95% limits of agreement −5.6 to +5.5 mm Hg
- pH: venous–arterial correlation r
- 0.94 (P < 0.0001)
- pH: median difference estimated vs measured
- −0.002 pH units; 95% limits of agreement −0.05 to +0.04 pH units
- HCO3- (Henderson-Hasselbalch from estimated pCO2 and pH): median difference vs reported
- −0.08 mEq/L; 95% limits of agreement −2.29 to +1.96 mEq/L
Original publication
Transforming the Venous Blood Gas to the Arterial Blood Gas from Concurrent Measurements. Kidney360. Published 2 January 2026. doi:10. 34067/ kid. 0000001113
Composed by AI from the published abstract and checked against it. How Briefs are made →