Thromboelastography and Traditional Coagulation Testing in Non-ICU-Admitted Patients with Acute Kidney Injury: An Observational Cohort Study
Authors' conclusion
Most non-ICU-admitted patients with AKI had normal-to-enhanced hemostasis and activated platelet function based on TEG results, as well as a high rate of premature circuit clotting when receiving heparin-free protocol despite thrombocytopenia. Further studies are needed to better determine the use of TEG in respect to management of anticoagulation and bleeding complications in AKI patients with KRT.
Study context
- Population
- Non-ICU-admitted patients with acute kidney injury (AKI) requiring intermittent kidney replacement therapy (KRT), at risk of bleeding and against systemic anticoagulant use during KRT, April–December 2018
- Participants
- 64 patients
- Exposure
- Heparin-free protocol vs regional citrate anticoagulation (RCA) during intermittent KRT
- Heparin-freen = 41
- RCAn = 23reference
- Outcome
- Premature termination of treatment due to circuit clotting (poor outcome)
Main finding
As reported in the abstract
P = 0.006
Key notes
- Heparin-free protocol was the strongest adverse factor to poor outcomes
Observational data: associations, not effects.
Further findings
Circuit clotting risk, heparin-free subgroup
| OR | P value | |
|---|---|---|
| 10 × 109/L elevation in platelet countRisk increased by 61.7% | 1.617 | P = 0.049 |
| Second increase of PTRisk decreased by 67.5% | 0.325 | P = 0.041 |
| Outcome | Estimate | P value |
|---|---|---|
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · lower with thrombocytopenia | fibrinogen 2.6 vs. 4.0 g/L | P = 0.00 |
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · lower with thrombocytopenia | α-angle 63.5° vs. 73.3° | P = 0.00 |
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · lower with thrombocytopenia | MA 53.5 vs. 66.1 mm | P = 0.00 |
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · lower with thrombocytopenia | coagulation index 1.8 vs. 3.6 | P = 0.00 |
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · higher with thrombocytopenia | thrombin time 17.8 vs. 16.2 s | P = 0.00 |
| Coagulation parameters, thrombocytopenia vs platelet count over 100 × 109/LThrombocytopenia vs Platelet count over 100 × 109/L · higher with thrombocytopenia | K-time 2.0 vs. 1.2 min | P = 0.00 |
Hypocoagulability on traditional parameters (prothrombin time (PT)/INR, activated partial PT, fibrinogen)
- Patients with hypocoagulability
- 4.7%-15.6%
Hypocoagulability on thromboelastography (TEG)
- Reaction time
- 0
- Kinetic time (K-time)
- 2.1%
- α-angle
- 3.1%
- Maximum amplitude (MA)
- 10.9%
- 37.5% of the cohort had thrombocytopenia
Hypercoagulability on TEG
- K-time
- 12.5%
- α-angle
- 43.8%
- MA
- 21.9%
- Coagulation index
- 48.4%
- Thrombocytosis in 1.5% of the cohort
Circuit clotting risk, heparin-free subgroup
- No significant correlation between TEG parameters and premature circuit clotting
Original publication