The use of medium cutoff dialyzers in patients with multiple myeloma and acute kidney injury requiring hemodialysis: A systematic review
Authors' conclusion
MCO dialyzer appeared to be effective in the removal of FLC based on the existing limited data. However, more data, particularly large-scale RCTs, are needed to assess the use of MCO dialyzer in reducing serum FLC and its effect on clinical outcomes in patients with multiple myeloma and AKI.
Study context
- Population
- Patients with multiple myeloma and acute kidney injury (AKI) requiring hemodialysis (HD)3 case series
- Participants
- 17 patients
- Comparison
- Medium cutoff (MCO) dialyzer vs other forms of dialyzers
- Outcome
- Effectiveness of MCO-HD in reducing serum FLC
Main finding
As reported in the abstract
Removal of FLC
- MCO dialyzer was effective in the removal of free light chains (FLC) and led to a reduction in FLC concentration post-dialysis
- No randomized controlled trials (RCTs) or cohort studies; most case series had no comparator arm and no renal or other clinical outcomes
Original publication
The use of medium cutoff dialyzers in patients with multiple myeloma and acute kidney injury requiring hemodialysis: A systematic review. Semin Dial. Published 15 July 2022. doi:10. 1111/ sdi. 13115