The role of a “volume sparing” strategy in kidney replacement therapy of acute kidney injury (AKI): a retrospective single-center study
Authors' conclusion
In this single-center retrospective study, low effluent volume CRRT-PIRRT was associated with similar outcomes to standard effluent volume CRRT-PIRRT, which is consistent with the results of prior observational studies. Randomized controlled studies comparing low effluent volume with standard effluent volume are needed.
Study context
- Population
- AKI patients treated with CRRT-PIRRT; AKI caused by metformin-induced lactic acidosis excluded
- Participants
- 36 vs 36
- Exposure
- Low effluent volume CRRT-PIRRT vs standard effluent volume continuous renal replacement therapy (CRRT)
- Low effluent volumen = 36
- Standard effluent volumen = 36reference
- Outcome
- Mortality within 90 days, shift from low to standard effluent volume due to dialysis inadequacy, and remission of AKI
- Follow-up
- 90 days
Methodological detailssingle-center
- Single-center
Main finding
As reported in the abstract
Death from any cause at 90 days, recovery of renal function, and shift to standard effluent volume
- No differences between the 2 groups in death from any cause at 90 days and recovery of renal function
- No patient switched from low to standard effluent volume due to inadequate control of uremic toxins
Observational data: associations, not effects.
Further findings
| Outcome | Low effluent volume | Standard effluent volume | P value |
|---|---|---|---|
| SCr at hospital discharge in patients with no KRT dependence | 1.9 ± 0.5 | 2.1 ± 0.6 mg/dl | P = 0.37 |
UKt/V per session
- Low effluent volume, CRRT
- 0.51 ± 0.04
- Low effluent volume, PIRRT
- 0.50 ± 0.07
- Standard effluent volume, CRRT
- 1.00 ± 0.02
- Standard effluent volume, PIRRT
- 0.95 ± 0.05
Metabolic, electrolyte and acid-base control
- All low effluent volume patients showed adequate metabolic, electrolyte, and acid-base profile control
Safety
Events
| Outcome | Low effluent volume | Standard effluent volume | P value |
|---|---|---|---|
| HypophosphatemiaLower incidence with low effluent volume | 5 | 15 | P = 0.003 |
Original publication
The role of a “volume sparing” strategy in kidney replacement therapy of AKI: a retrospective single-center study. J Nephrol. Published 9 January 2025. doi:10. 1007/ s40620-024-02142-z