The Long‐Term Patency Rate and Factors Influencing Dysfunction of the Autogenous Arteriovenous Fistula in Hemodialysis Patients: A Retrospective Study
Authors' conclusion
Our study findings indicated that overweight, hypoalbuminemia, and high concentrations of uric acid were independent risk factors for AV fistula dysfunction. In contrast, preemptive AV fistula creation was an independent protective factor against AV fistula dysfunction. Therefore, early interventions and surveillance for these factors should be performed to improve long-term AV fistula patency rates.
Study context
- Population
- HD patients who underwent AVF creation at a tertiary A-level hospital in Chongqing, China
- Participants
- 226 patients
- Outcome
- Long-term AVF patency rate and factors influencing AVF dysfunction
Methodological detailssingle-centre, tertiary A-level hospital, Cox proportional hazards regression, Kaplan-Meier survival analysis
- Single-centre
- Tertiary A-level hospital
- Cox proportional hazards regression
- Kaplan-Meier survival analysis
Main finding
As reported in the abstract
Cumulative AVF patency at 12 months
82.1%
Cumulative AVF patency at 36 months
60.7%
Cumulative AVF patency at 60 months
45.4%
Cumulative AVF patency at 84 months
33.5%
Further findings
Independent predictors of AV fistula dysfunction (multivariate Cox regression)
| HR | P value | |
|---|---|---|
| Elevated BMI | 1.58 | P = 0.016 |
| Preemptive AV fistula creation | 0.67 | P = 0.029 |
| Albumin | 2.83 | P < 0.001 |
| Uric acid | 1.57 | P = 0.020 |
Variables associated with AV fistula dysfunction (univariate Cox regression)
- Six variables associated with AV fistula dysfunction (p < 0.1): Body mass index (BMI), preemptive AV fistula creation, diabetes, total cholesterol, albumin and uric acid