The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis
Authors' conclusion
Employing automated urinalysis seems to be accurate for detecting hematuria and leukocyturia, as well as for screening patients without kidney diseases. However, clinical laboratories attending complex patients should employ personalized strategies to help decide when to perform manual review, thus avoiding misleading urinalysis results.
Study context
- Population
- Urine samples randomly selected from routine laboratory specimens at a university hospital, patients with and without kidney disease503 samples
- Comparison
- Laboratory automated urinalysis vs reference manual microscopy
- Outcome
- Accuracy of laboratory urinary sediment analysis vs standardized microscopic review
Methodological detailssingle university hospital, random sampling of routine specimens, double-blinded reference analysis
- Single university hospital
- Random sampling of routine specimens
- Double-blinded reference analysis
Performance
As reported in the abstract
Accuracy of laboratory urinalysis vs reference analysis
| Test or model | Overall agreement | Pathological casts, lipiduria, renal tubular epithelial cells: sensitivity | Pathological casts, lipiduria, renal tubular epithelial cells: specificity | Hyaline casts: sensitivity | Hyaline casts: specificity | Dysmorphic RBCs: sensitivity | Dysmorphic RBCs: specificity | Hematuria: sensitivity | Hematuria: specificity | Hematuria: ICC | Hematuria: R | Leukocyturia: sensitivity | Leukocyturia: specificity | Leukocyturia: ICC | Leukocyturia: R |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Laboratory | 42.1% | <50% | >98% | 50.4% | 80.9% | 62.3% | 96.2% | 86.1% | 82.3% | 0.703 | 0.828 | 84.9% | 95.1% | 0.807 | 0.861 |
Laboratory
Overall agreement42.1%
Pathological casts, lipiduria, renal tubular epithelial cells: sensitivity<50%
Pathological casts, lipiduria, renal tubular epithelial cells: specificity>98%
Hyaline casts: sensitivity50.4%
Hyaline casts: specificity80.9%
Dysmorphic RBCs: sensitivity62.3%
Dysmorphic RBCs: specificity96.2%
Hematuria: sensitivity86.1%
Hematuria: specificity82.3%
Hematuria: ICC0.703
Hematuria: R0.828
Leukocyturia: sensitivity84.9%
Leukocyturia: specificity95.1%
Leukocyturia: ICC0.807
Leukocyturia: R0.861
Key notes
- 52.3% of samples from nephrology outpatient clinic patients
Further findings
| Outcome | P value |
|---|---|
| Identification of elements suggestive of nephropathyLaboratory, manually reviewed samples vs Reference | P = 0.503 |
- Identification of elements suggestive of nephropathy: only manually reviewed samples statistically similar to reference
Accuracy in patients with kidney disease and in samples manually reviewed by the laboratory
- Accuracy for each urinary element comparable to the overall sample findings
- Kidney disease N = 248; manually reviewed N = 115
Original publication
The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis. Am J Nephrol. Published 16 October 2024. doi:10. 1159/ 000541561