Acute kidney injury

Successful Application of a Hemoperfusion Machine in Separated System Continuous Renal Replacement Therapy (CRRT): Evaluating Effectiveness and Safety in Critically Ill Patients With Acute Kidney Injury (AKI) in Resource‐Limited Settings

Semin DialPublished Retrospective cohort study

Authors' conclusion

Separated system CRRT using a hemoperfusion machine provides a simplified system to operate and is proven to be effective and safe in real-life practice, especially in resource-limited areas.

Study context

Population
Critically ill patients with AKI, January 2015 to December 2021
Participants
129 patients
Outcome
Effectiveness and safety of separated CRRT applied from a hemoperfusion machine
Methodological detailssingle-group, multivariate logistic regression analysis
  • Single-group
  • Multivariate logistic regression analysis

Main finding

As reported in the abstract

In-hospital mortality rate

68.9%

Serious complications including circuit explosion and air embolism

0

Mean prescribed CRRT dose (mL/kg/h)

22.4 ± 3.1

Further findings

Baseline at CRRT initiation

SOFA score
12.6 ± 3.8
Fluid accumulation
3900 mL (622-8172 mL)

Safety

No serious complications including circuit explosion and air embolism

Original publication

Successful Application of a Hemoperfusion Machine in Separated System CRRT: Evaluating Effectiveness and Safety in Critically Ill Patients With AKI in Resource‐Limited Settings. Semin Dial. Published 21 May 2024. doi:10.1111/sdi.13210

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.