Genetic & cystic kidney disease

Renal Volume Measurement in Autosomal Dominant Polycystic Kidney Disease (ADPKD): Agreement of SuperWide View and 3D Ultrasound Techniques with Computed Tomography (CT)

J NephrolPublished agreement study of SuperWide View (SWV) 2D and S3D ultrasound kidney volume measurements with CT-derived volumes

Authors' conclusion

S3D US showed strong correlations with CT-derived kidney volumes. However, the relatively wide limits of agreement and the finding that only approximately 62-65% of 4-plane measurements were within ±15% of CT-derived values indicate that US and CT measurements are not interchangeable at the individual-patient level. S3D US may nevertheless provide a useful noninvasive approach for kidney volume assessment in selected patients with ADPKD.

Study context

Population
Patients with ADPKD who underwent ultrasound (US) and CT within 3 months
Participants
67 patients
Exposure
SWV 2D and S3D kidney volume measurements vs CT-derived volumes
Outcome
Correlation of US methods with CT measurements
Methodological detailstwo sonographers independently measured kidney volumes, S3D with 2, 4, and 8 cross-sectional planes, Bland-Altman analyses
  • Two sonographers independently measured kidney volumes
  • S3D with 2, 4, and 8 cross-sectional planes
  • Bland-Altman analyses

Main finding

As reported in the abstract

Correlation of US methods with CT measurements
All US methods correlated strongly with CT measurements, r
≥ 0.89
p
p < 0.0001

Observational data: associations, not effects.

Further findings

Intraclass correlation coefficients

Intraclass correlation coefficients (ICCs)
0.875-0.952

Median percentage error, 4-plane S3D method

Examiner A
3.8%
Examiner B
−1.0%
The 4-plane S3D method had the lowest median percentage errors

Measurements within ±15% of CT-derived values

Examiner A
65.3%
Examiner B
61.8%

Bland-Altman analysis

No fixed bias was observed
Bland-Altman limits of agreement were relatively wide

Original publication

Renal Volume Measurement in ADPKD: Agreement of SuperWide View and 3D Ultrasound Techniques with CT. J Nephrol. Published 21 November 2026. doi:10.1093/joneph/aajag282

Composed by AI from the published abstract and checked against it. How Briefs are made →