Genetic & cystic kidney disease
Renal Volume Measurement in Autosomal Dominant Polycystic Kidney Disease (ADPKD): Agreement of SuperWide View and 3D Ultrasound Techniques with Computed Tomography (CT)
Authors' conclusion
S3D US showed strong correlations with CT-derived kidney volumes. However, the relatively wide limits of agreement and the finding that only approximately 62-65% of 4-plane measurements were within ±15% of CT-derived values indicate that US and CT measurements are not interchangeable at the individual-patient level. S3D US may nevertheless provide a useful noninvasive approach for kidney volume assessment in selected patients with ADPKD.
Study context
- Population
- Patients with ADPKD who underwent ultrasound (US) and CT within 3 months
- Participants
- 67 patients
- Exposure
- SWV 2D and S3D kidney volume measurements vs CT-derived volumes
- Outcome
- Correlation of US methods with CT measurements
Methodological detailstwo sonographers independently measured kidney volumes, S3D with 2, 4, and 8 cross-sectional planes, Bland-Altman analyses
- Two sonographers independently measured kidney volumes
- S3D with 2, 4, and 8 cross-sectional planes
- Bland-Altman analyses
Main finding
As reported in the abstract
- All US methods correlated strongly with CT measurements, r
- ≥ 0.89
- p
- p < 0.0001
Observational data: associations, not effects.
Further findings
Intraclass correlation coefficients
- Intraclass correlation coefficients (ICCs)
- 0.875-0.952
Median percentage error, 4-plane S3D method
- Examiner A
- 3.8%
- Examiner B
- −1.0%
- The 4-plane S3D method had the lowest median percentage errors
Measurements within ±15% of CT-derived values
- Examiner A
- 65.3%
- Examiner B
- 61.8%
Bland-Altman analysis
- No fixed bias was observed
- Bland-Altman limits of agreement were relatively wide
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →