Relative Blood Volume Monitoring during Continuous Renal Replacement Therapy: A Prospective Observational Study
Authors' conclusion
Continuous hematocrit and RBV monitoring during CRRT was feasible. RBV decreased significantly during CRRT, and decreases were greater with higher NUF rates. RBV monitoring may help optimize NUF management and prevent the occurrence of intravascular volume depletion.
Study context
- Population
- Adult ICU patients receiving continuous renal replacement therapy (CRRT)>1,000 CRRT hours
- Participants
- 36 patients
- Exposure
- High vs low or moderate net ultrafiltration (NUF) rates
- Outcome
- Feasibility of extended RBV monitoring and its epidemiology during usual CRRT management
Methodological detailscontinuous pre-filter noninvasive optical sensor monitoring, clinicians unaware of relative blood volume (RBV)
- Continuous pre-filter noninvasive optical sensor monitoring
- Clinicians unaware of RBV
Main finding
As reported in the abstract
RBV change during CRRT
- Minute-by-minute measurements obtained
- >60,000
- Patients with negative median RBV change (decrease)
- 69%
- Median peak change in RBV
- −9.3% (IQR −3.9% to −14.3%)
- Measurements with median RBV decrease from baseline >5%
- 40.2%
- Measurements with median RBV decrease from baseline >10%
- 20.6%
Observational data: associations, not effects.
Further findings
RBV decrease by NUF rate — High NUF rate vs Low or moderate NUF rate · RBV decreased significantly more with high NUF rate
P < 0.001
Original publication
Relative Blood Volume Monitoring during Continuous Renal Replacement Therapy: A Prospective Observational Study. Blood Purif. Published 13 August 2024. doi:10. 1159/ 000540838
Composed by AI from the published abstract and checked against it. How Briefs are made →