Recalibration of the European Kidney Function Consortium eGFR Equation for the Indian Population
Authors' conclusion
Recalibrating EKFCcrea with Indian-specific Q and K reduced bias and improved accuracy, with EKFCISK emerging as the best model. Adopting this recalibrated equation in clinical practice and public health initiatives after validation in diverse cohorts could lead to more accurate CKD diagnosis and staging in India.
Study context
- Population
- Indian adults, healthy and with chronic kidney disease (CKD)615 healthy, 559 CKD
- Participants
- 1,174 adults
- Comparison
- EKFCcrea, CKD-EPI 2021 and recalibrated EKFCcrea vs measured GFR (mGFR)
- Outcome
- Bias and accuracy (P30) vs mGFR
Methodological detailsrecalibration of EKFCcrea with Indian-specific Q and K, plasma iohexol clearance as mGFR
- Recalibration of EKFCcrea with Indian-specific Q and K
- Plasma iohexol clearance as mGFR
Performance
As reported in the abstract
EKFCcrea mean bias 9.9 (95% CI 8.7–11.1) ml/min per 1.73 m² · EKFCISQ bias 4.9 (95% CI 3.7 6.0) ml/min per 1.73 m² · EKFCISK bias −1.2 (95% CI −0.1–-2.2) ml/min per 1.73 m²
P30
Further findings
CKD patients categorised into lower CKD categories vs CKD-EPI 2021
Original publication
Recalibration of the European Kidney Function Consortium eGFR Equation for the Indian Population. Kidney Int Rep. Published 15 April 2026. doi:10. 1016/ j. ekir. 2026. 106543