Quantifying ultrasound echogenicity difference for accurate chronic kidney disease diagnosis
Authors' conclusion
The radiologists' visual analysis of renal echogenic characteristics is insufficient for CKD diagnosis. Quantitative echogenicity analysis using the proposed echogenicity difference values is more objective and effective for diagnosing CKD.
Study context
- Population
- Patients with kidney disease undergoing US and SCr tests; Chronic kidney disease (CKD) vs non-CKD classified by estimated glomerular filtration rate (eGFR)
- Participants
- 339 patients
- Comparison
- Radiologists' visual assessment vs quantitative echogenicity difference values on US for CKD diagnosis
- Outcome
- Diagnostic accuracy for CKD (ROC curves)
Methodological detailssingle-centre, ROC analysis, September 2018 to December 2019
- Single-centre
- ROC analysis
- September 2018 to December 2019
Performance
As reported in the abstract
Diagnostic performance for CKD
| Test or model | AUC | Sensitivity | Specificity | Accuracy |
|---|---|---|---|---|
| Radiologists' visual analysis | — not stated in the abstract | — not stated in the abstract | — not stated in the abstract | 42.5-46.9% |
| Right sinus–cortex difference | 0.838 | 68.45% | 87.13% | 77.90% |
| Left sinus–cortex difference | 0.805 | 70.24% | 80.12% | 75.22% |
AUC
Radiologists' visual analysis— not stated in the abstract
Right sinus–cortex difference0.838
Left sinus–cortex difference0.805
Sensitivity
Radiologists' visual analysis— not stated in the abstract
Right sinus–cortex difference68.45%
Left sinus–cortex difference70.24%
Specificity
Radiologists' visual analysis— not stated in the abstract
Right sinus–cortex difference87.13%
Left sinus–cortex difference80.12%
Accuracy
Radiologists' visual analysis42.5-46.9%
Right sinus–cortex difference77.90%
Left sinus–cortex difference75.22%
— not stated in the abstract
Further findings
Correlation with eGFR
- Bilateral mid-renal cortex echogenicity and echogenicity difference value strongly correlated with eGFR
Original publication
Quantifying ultrasound echogenicity difference for accurate chronic kidney disease diagnosis. J Nephrol. Published 30 July 2025. doi:10. 1007/ s40620-025-02352-z
Composed by AI from the published abstract and checked against it. How Briefs are made →