Pediatric nephrology

Prediction of split renal function and obstruction with magnetic resonance urography in comparison with dynamic renal scintigraphy

Pediatr NephrolPublished Diagnostic accuracy study

Authors' conclusion

MRU could be an invaluable tool in the assessment of renal functions. Its diagnostic accuracy in detecting the level and extent of obstruction is comparable to that of MAG3 scintigraphy. Despite the lack of extensive comparative data, the potential benefits of MRU justify the need for further studies.

Study context

Population
Children who had previously undergone MAG3 scintigraphy, aged 1 to 216 months
Participants
76 children
Comparison
Dynamic contrast-enhanced magnetic resonance urography (MRU) vs MAG3 scintigraphy
Outcome
Prediction of obstruction by MRU RTT (cut-off 11.5 min) and SRF agreement with scintigraphy
Methodological detailsretrospective comparison with MAG3 scintigraphy, CHOP-fMRU software, ROC analysis
  • Retrospective comparison with MAG3 scintigraphy
  • CHOP-fMRU software
  • ROC analysis

Performance

As reported in the abstract

MRU

Sensitivity

94%

Specificity

86%

Positive predictive value

90%

Negative predictive value

88%

Accuracy 88%

Positive correlation between split renal functions (SRFs) of right and left kidneys measured by MRU and scintigraphy (r > 0.9)
P = 0.001

Original publication

Prediction of split renal function and obstruction with magnetic resonance urography in comparison with dynamic renal scintigraphy. Pediatr Nephrol. Published 17 February 2026. doi:10.1007/s00467-026-07211-y

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.