Prediction of Intradialytic Blood Pressure Variation Based on Big Data
Authors' conclusion
This databae supported our prediction model in reducing the frequency of intradialytic SBP variability, which may help in clinical decision-making when a new patient receives HD treatment. Further investigations are needed to determine whether the introduction of the intelligent SBP prediction system decreases the incidence of CV events in HD patients.
Study context
- Population
- Hemodialysis (HD) patients; dialysis parameters collected via the Vital Info Portal gateway linked to hospital information system demographic data542,424 blood pressure (BP) records
- Comparison
- Test vs New
- Outcome
- Prediction of SBP change during HD (accuracy as coverage rates at different thresholds)
Methodological detailsmultiple linear regression model, training, test and new patient groups, web-based interactive system
- Multiple linear regression model
- Training, test and new patient groups
- Web-based interactive system
Performance
As reported in the abstract
Accuracy of the model of SBP changes
Accuracy in the prediction error range of 15%, and 20 mm Hg of true systolic BP (SBP) in the test and new patient groups
greater than 80%
Further findings
Accuracy of prediction of absolute SBP values
- Accuracy of SBP prediction increased as the threshold value (5, 10, 15, 20, and 25 mm Hg) increased
Original publication
Prediction of Intradialytic Blood Pressure Variation Based on Big Data. Blood Purif. Published 8 March 2023. doi:10. 1159/ 000527723
Composed by AI from the published abstract and checked against it. How Briefs are made →