Practical implementation and clinical benefits of the new automated dialysate sodium control biosensor
Authors' conclusion
The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.
Study context
- Population
- Dialysis patients
- Participants
- 86 patients
- Exposure
- Activated automated dialysate Na control biosensor (isonatraemic dialysis) vs baseline 5008 machine and 6008 machine without activated Na control
- Outcome
- Serum Na and Na balance with activated Na control
Methodological detailsfive consecutive phases of 3 weeks each
- Five consecutive phases of 3 weeks each
Main finding
As reported in the abstract
- Activated Na control showed significant differences vs baseline and non-activated Na module in final serum Na values, diffusive Na balance, and pre- to postdialysis plasma Na changes
- No significant differences in total Na balance in the four 6008 phases
Observational data: associations, not effects.
Further findings
- Mean predialysis systolic BP significantly lower in phase 4 than in phase 1
Safety
- With activated Na control, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L
Original publication
Practical implementation and clinical benefits of the new automated dialysate sodium control biosensor. Clin Kidney J. Published 23 January 2023. doi:10. 1093/ ckj/ sfad013