PHYOX3: Nedosiran Long-Term Safety and Efficacy in Patients With Primary Hyperoxaluria Type 1
Authors' conclusion
Nedosiran was well-tolerated, reduced average Uox levels, reduced kidney stone occurrence, and maintained stable renal function for over 3 years.
Study context
- Population
- Participants with PH1 from PHYOX1 and PHYOX2 trialsPHYOX1 n = 13
- Participants
- 40 participants
- Outcome
- eGFR
- Follow-up
- Up to 42 months
Methodological detailsinterim analysis, single-arm
- Interim analysis
- Single-arm
Main finding
As reported in the abstract
Mean estimated glomerular filtration rate (eGFR) range throughout the study
71.1 to 81.5 ml/min per 1.73 m²
Baseline mean eGFR (SD)
80.0 (28.6) ml/min per 1.73 m²
Key notes
- Interim analysis
Further findings
24-hour urinary oxalate (Uox) excretion · month 4 to month 42
- Mean 24-hour Uox excretion declined by
- ˃ 60%
- Maintained from month 4 to month 42
Annualized stone event rate
- Baseline
- 0.40
- During study
- 0.20 (22 events/108.8 person-years)
Deaths
- No deaths reported
Safety
Serious adverse events (AEs)
- Participants with ≥ 1 serious AE, none associated with nedosiran
- 8
Nonserious treatment-related AEs: injection site reactions (most common)
- Injection site reactions
- 6 participants; 15%
Treatment discontinuation
- Participants who discontinued treatments (1 pregnancy and 3 withdrawals)
- 4
Original publication
PHYOX3: Nedosiran Long-Term Safety and Efficacy in Patients With Primary Hyperoxaluria Type 1. Kidney Int Rep. Published 25 March 2025. doi:10. 1016/ j. ekir. 2025. 03. 031
Composed by AI from the published abstract and checked against it. How Briefs are made →