Perioperative fluid management and associated complications in children receiving kidney transplants in the UK
Authors' conclusion
This study describes a high degree of variability in perioperative fluid volumes administered to children receiving kidney transplants. Both fluid volume and urine output were negatively associated with short-term graft function. These data contrast traditional interpretation of high urine output as a marker of graft health, and highlight the need for prospective clinical trials to optimise perioperative fluid administration for this group.
Study context
- Population
- Children <18 years receiving a kidney-only transplant between 1st January 2020 and 31st December 2021 in 5 UK paediatric centres
- Participants
- 102 children
- Outcome
- Volume of perioperative fluids administered
- Follow-up
- 72 h
Methodological details5 UK paediatric kidney transplant centres
- 5 UK paediatric kidney transplant centres
Main finding
As reported in the abstract
All children
377
median · IQR 149 ml/kg · ml/kg
Key notes
- High degree of variability
Further findings
Total fluid volume and day 7 eGFR
- Negative relationship between total fluid volume administered and day 7 eGFR
- P < 0.001
Urine volume post-transplant and day 7 eGFR
- Negative association between urine volume post-transplant and day 7 eGFR
- P < 0.001
Safety
Adverse events (pulmonary oedema, systemic hypertension, ICU support)
- Adverse events frequent; no significant difference in fluid volume administered between those with vs without an adverse event