Performance of Glomerular Filtration Rate (GFR) Estimation in Finnish Children and Adolescents
Authors' conclusion
Combination equations provided more accurate estimates of GFR than single-analyte equations. Selected combination equations accurately estimated GFR across all age groups, a finding that is likely population dependent.
Study context
- Population
- Finnish patients under the age of 20 years with GFR measured, with a history of solid organ transplantation, malignancy, or suspected kidney impairmentaged 0.8 to 19.9 years
- Participants
- 516 participants
- Exposure
- Creatinine-cystatin C combination equations vs single-analyte GFR estimating equations, each vs measured GFR (mGFR)
- Outcome
- Performance of GFR estimating equations vs mGFR: bias, precision, and accuracy
Methodological detailssingle-centre, diagnostic accuracy of GFR estimating equations vs mGFR, GFR measured between September 2014 and April 2025; data collected retrospectively from the Helsinki University Hospital electronic data lake
- Single-centre
- Diagnostic accuracy of GFR estimating equations vs mGFR
- GFR measured between September 2014 and April 2025; data collected retrospectively from the Helsinki University Hospital electronic data lake
Main finding
As reported in the abstract
Performance of GFR estimating equations vs mGFR
| Group | Value | IQR | P10 accuracy | P30 accuracy |
|---|---|---|---|---|
| CKiD (2012) combination equation | median bias 0.1 ml/min per 1.73 m² | 14.6 ml/min per 1.73 m² | 47.3% | 94.6% |
| Other combination equations | median bias between 2.6 and 4.0 ml/min per 1.73 m² | — not stated in the abstract | — not stated in the abstract | between 86.4% and 90.1% |
Value
CKiD (2012) combination equationmedian bias 0.1 ml/min per 1.73 m²
Other combination equationsmedian bias between 2.6 and 4.0 ml/min per 1.73 m²
IQR
CKiD (2012) combination equation14.6 ml/min per 1.73 m²
Other combination equations— not stated in the abstract
P10 accuracy
CKiD (2012) combination equation47.3%
Other combination equations— not stated in the abstract
P30 accuracy
CKiD (2012) combination equation94.6%
Other combination equationsbetween 86.4% and 90.1%
Key notes
- Creatinine-cystatin C-based combination equations exhibited better performance than single-analyte equations
- CKiD (2012) combination equation had the lowest median bias and IQR and the highest P10 and P30 accuracies
More notes
- CKiD (2012) combination equation surpassed the P30 threshold of 90% in all age groups
- Other combination equations: similar median bias and P30 accuracy, with overlapping 95% confidence intervals (CIs)
- CKiD (2012) developed using cystatin C not calibrated to IFCC reference material
Observational data: associations, not effects.
Original publication
Performance of GFR Estimation in Finnish Children and Adolescents. Kidney Int Rep. Published 17 September 2026. doi:10. 1016/ j. ekir. 2026. 107082
Composed by AI from the published abstract and checked against it. How Briefs are made →