Glomerular disease

Multiplexed Detection of Membranous Nephropathy Antigens by Multi-Reaction Monitoring Mass Spectrometry

Kidney Int RepPublished Diagnostic accuracy study

Authors' conclusion

MRM-MS following protein A/G immunoprecipitation of MN biopsy tissue can be effectively used for multiplex antigen typing in clinical nephropathology practice.

Study context

Population
Membranous nephropathy (MN) cases with kidney biopsy and antigen type confirmed by immunostaining
Participants
113 cases
Comparison
MRM-MS after protein A/G immunoprecipitation vs immunostaining for MN antigen typing
Outcome
Diagnostic accuracy, sensitivity and specificity for identifying MN antigens in kidney biopsies
Methodological detailsassay development and validation, immunostaining as independent reference method
  • Assay development and validation
  • Immunostaining as independent reference method

Performance

As reported in the abstract

Diagnostic performance for MN antigen typing

Mass spectrometry (MS)-enabled workflow

Sensitivity

97.2%

Specificity

100%

Accuracy 97.2%

Reliable quantitative detection of MN antigens
19

Further findings

Antigens detected

Reliable quantitative detection of MN antigens
19

Original publication

Multiplexed Detection of Membranous Nephropathy Antigens by Multi-Reaction Monitoring Mass Spectrometry. Kidney Int Rep. Published 22 April 2026. doi:10.1016/j.ekir.2026.106561

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.