Hemodialysis

Modifiable Factors Associated with Prolonged Dialysis Recovery Time and Fatigue in Hemodialysis Patients

Kidney360Published Multicenter observational study

Authors' conclusion

Modifiable factors associated with prolonged DRT are not exactly similar to those associated with fatigue. Intradialytic reduction in serum sodium and low frequency of dialysis are two independent factors associated with longer DRT, with hemodiafiltration associated with longer recovery in very elderly patients. The hemoglobin level is the modifiable independent factor associated with fatigue. These modifiable factors can be addressed in future interventional trials to improve patients' outcomes.

Study context

Population
Adults on chronic HD for >3 months during December 2023; excluding hospitalised patients and those with cognitive problems or active cancer2,967 sessions analysed
Participants
536 adults
Outcome
Dialysis recovery time (DRT) >12 hours and fatigue score ≥4 (SONG-HD fatigue scale)
Methodological detailsmultivariable logistic regression
  • Multivariable logistic regression

Main finding

As reported in the abstract

Median dialysis recovery time (DRT), minutes
140 (45-440)
DRT >12 hours
14.9%
Fatigue score
3.1±2.3
No fatigue
18%
Fatigue score ≥4
37.7%

Further findings

DRT in patients aged ≥85 years

HDF associated with prolonged DRT

Original publication

Modifiable Factors Associated with Prolonged Dialysis Recovery Time and Fatigue in Hemodialysis Patients. Kidney360. Published 2 August 2024. doi:10.34067/kid.0000000000000532