Peritoneal & home dialysis

Mesenteric elasticity assessed by shear wave elastography and its relationship with peritoneal function in peritoneal dialysis patients

Clin Kidney JPublished Cross-sectional study

Authors' conclusion

SWE could be used to non-invasively characterize peritoneal textural changes, which were closely associated with changes in peritoneal function.

Study context

Population
Patients undergoing continuous ambulatory peritoneal dialysis (CAPD) in one peritoneal dialysis (PD) centre, recruited 15 July 2019 to 31 December 2021
Participants
218 PD patients
Exposure
Mesenteric shear wave elastography (SWE) values by PD duration vs chronic kidney disease (CKD) patients and healthy controls
  • CKDn = 12
  • Healthy controlsn = 19
Outcome
Mesenteric elasticity by SWE and its relationship with peritoneal function
Methodological detailssingle-centre, correlation, linear regression and Cox regression analyses
  • Single-centre
  • Correlation, linear regression and Cox regression analyses

Main finding

As reported in the abstract

Mesenteric SWE value

PD <3 months vs CKD: P = 0.17 · PD <3 months vs Healthy controls: P = 0.13 · PD <3 months vs PD 3 months-5 years: P < 0.001 · PD <3 months vs PD 5-10 years: P < 0.001 · PD <3 months vs PD >10 years: P < 0.001

Median mesenteric SWE value, all PD patients
8.15 kPa (IQR 5.20-16.1)

Observational data: associations, not effects.

Further findings

Death-censored technique failure · followed up to 31 March 2022

aHR (95% CI)P value
High mesenteric SWE valuesIndependent risk factor4.14 (1.25–13.7)P = 0.02

Factors independently associated with low mesenteric elasticity

Longer PD duration
β = 0.58, P < .001
High effluent interleukin-6
β = 0.61, P = .001
Low effluent cancer antigen 125
β = −0.34, P = .03

Mesenteric SWE value and peritoneal function

Independent correlation with dialysate:plasma creatinine ratio
β = 0.39, P = .01
Negative correlation with total daily fluid volume removed
β = −0.17, P = .03

Original publication

Mesenteric elasticity assessed by shear wave elastography and its relationship with peritoneal function in peritoneal dialysis patients. Clin Kidney J. Published 25 August 2022. doi:10.1093/ckj/sfac192

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.