Machine learning does not outperform traditional statistical modelling for kidney allograft failure prediction
Authors' conclusion
Thus, when using a transparent methodological pipeline in validated international cohorts, ML models, despite overall good performances, do not outperform a traditional CBPS in predicting kidney allograft failure.
Study context
- Population
- Kidney transplant recipients from 14 centers worldwide; French derivation cohort (4000) and external validation cohorts from Europe (2214), North America (1537) and South America (671)1,081 (12.84%) graft losses
- Participants
- 8,422 recipients
- Comparison
- Machine learning (ML) models vs Cox-Based Prognostication System
- Outcome
- Prediction performance (C-index) for kidney allograft failure
- Follow-up
- Seven years post-risk evaluation
Methodological detailsmulticentre (14 centers worldwide), bootstrap percentile CI
- Multicentre (14 centers worldwide)
- Bootstrap percentile CI
Performance
As reported in the abstract
RSF
0.788
95% bootstrap percentile CI 0.736–0.833
RSF-ERT
0.779
95% bootstrap percentile CI 0.724–0.825
CIF
0.786
95% bootstrap percentile CI 0.735–0.832
LK-SVM
0.527
95% bootstrap percentile CI 0.456–0.602
AK-SVM
0.704
95% bootstrap percentile CI 0.648–0.759
XGBoost
0.767
95% bootstrap percentile CI 0.711–0.815
Cox-Based Prognostication System (CBPS)
0.808
95% bootstrap percentile CI 0.792–0.829
Further findings
Discrimination in validation cohorts
- ML models' discrimination in a similar range to the CBPS
Calibration
- Calibration of ML models similar or less accurate than the CBPS
Follow-up
- Median post-transplant follow-up, years
- 6.25 (IQR 4.33-8.73)
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →