Hemodialysis

Is Endovascular Arteriovenous Fistula a Feasible Alternative for Hemodialysis Patients?

Blood PurifPublished Prospective cohort study

Authors' conclusion

Based on our experience, creating AVFs using the WavelinQ 4-F EndoAVF System is safe and effective, with high technical success rates and acceptable patency and reintervention rates.

Study context

Population
Hemodialysis (HD) patients who underwent endovascular arteriovenous fistula (endoAVF) creation at a University Hospital between December 2021 and August 2023
Participants
20 patients
Outcome
Technical success, efficacy, and cannulation rates
Methodological detailssingle-center, single-arm
  • Single-center
  • Single-arm

Main finding

As reported in the abstract

Technical success, physiological suitability and cannulation
GroupTechnical successPhysiological suitabilityCannulation rate (endoAVFs reaching physiological suitability)
Endovascular arteriovenous fistulaendoAVF100%75% (15)66% (10/15)

Endovascular arteriovenous fistulaendoAVF

Technical success100%
Physiological suitability75% (15)
Cannulation rate (endoAVFs reaching physiological suitability)66% (10/15)

Secondary outcomes

Primary and cumulative patency · 6 months

Primary patency rate at 6 months
65%
Cumulative patency rate at 6 months
75%

Primary and cumulative patency · 12 months

Primary patency rate at 12 months
50%
Cumulative patency rate at 12 months
70%

Reintervention rate

Reintervention rate
0.33 procedures/patient-year

Safety

Serious adverse events were not observed

Original publication

Is Endovascular Arteriovenous Fistula a Feasible Alternative for Hemodialysis Patients? Blood Purif. Published 12 September 2024. doi:10.1159/000541233

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.