Intra-abdominal pressure in children receiving peritoneal dialysis for acute kidney injury
Authors' conclusion
Increased IAP (>10 mmHg) was common, although not associated with serious adverse events, and warrants monitoring in these patients. The pressures measured are different with the two techniques used, although they do correlate well.
Study context
- Population
- Critically ill children with AKI receiving peritoneal dialysis (PD); median (range) age 6.0 (0.2–14) months, weight 5.8 (2.3–14.0) kg
- Participants
- 15 children
- Comparison
- Conventional PD vs continuous flow PD
- Primary endpoint
- IAP and complications with a standard PD fill volume
Methodological detailsstandard PD fill volume
- Standard PD fill volume
Primary result
As reported in the abstract
Raised IAP (>10 mmHg) after filling
Children with raised intra-abdominal pressure (IAP) (>10 mmHg) after filling
9
60%
Secondary outcomes
Mean
| Outcome | Conventional PD | CFPD | P value |
|---|---|---|---|
| IAP measured directly (PD catheter via manometer) | 9.35 (SD 2.97) | 9.3 (SD 3.35) | P > 0.5 |
| IAP measured indirectly (intravesicular, bladder catheter to transducer) | 11.5 (SD 2.96) | 11.2 (SD 3.62) | P > 0.5 |
Agreement of intravesicular vs direct IAP measurement
- Pearson correlation coefficient (p < 0.001)
- 0.7
- ICC (moderate reliability)
- 0.6
- Intravesicular IAP constantly significantly higher than direct method (p = 0.002)
Safety
- No children developed compartment syndrome or other complications