Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume
Authors' conclusion
The volume achieved by convective transport can vary according to the type of biocontrol, with Max-Sub performing the best out of the 3 biocontrol systems. </p>.
Study context
- Population
- Prevalent patients on post-dilution online HDF
- Participants
- 13 patients
- Exposure
- Max-Sub vs UltraControl vs AutoSub+ biocontrol in post-dilution on-line hemodiafiltration (OL-HDF)
- Outcome
- Substitution (convective) volume achieved
Methodological detailscross-over
- Cross-over
Main finding
As reported in the abstract
Convective volume
- Max-Sub vs UltraControl: P = 0.009
- Max-Sub vs AutoSub+: P = 0.01
Observational data: associations, not effects.
Further findings
Factors associated with higher convective volume (multivariate analysis)
| B (95% CI) | P value | |
|---|---|---|
| Max-Sub prescription | 1.61 (0.41–2.80) | P = 0.009 |
| TPM | 0.02 (0.01–0.03) | P = 0.018 |
| Blood processed | 0.17 (0.08–0.26) | P < 0.001 |
| Diabetes mellitusNot having diabetes associated with higher volume | −1.66 (−2.72 to 0.59) | P = 0.002 |
Original publication
Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume. Blood Purif. Published 7 July 2025. doi:10. 1159/ 000546642
Composed by AI from the published abstract and checked against it. How Briefs are made →