Hemodialysis

Infectious complications associated with buttonhole cannulation of native arteriovenous fistulas: a 22-year follow-up

Nephrol Dial TransplantPublished Prospective cohort study

Authors' conclusion

The constant observance of reinforced hygiene protocols by trained staff and central coordination succeeded in significantly mitigating the infectious risk associated with buttonhole cannulation.

Study context

Population
In-center HD patients with a native AVF, 1 July 2010 to 31 December 2022, following a 2001–10 pre (rope-ladder (RL))-post (buttonhole (BH)) comparison366 arteriovenous fistulas (AVFs), 381,661 AVF-days
Participants
345 patients
Exposure
Six periods of cannulation technique and quality improvement strategies; Period 6 vs Periods 1, 3, 4 and 5
Outcome
Infectious events:
  • Unexplained bacteremia due to skin bacteria
  • Local AVF infection
Methodological detailssingle-centre, pre-post comparison, quality improvement periods
  • Single-centre
  • Pre-post comparison
  • Quality improvement periods

Main finding

As reported in the abstract

Incidence of infectious events
Incidence rate ratio (95% CI)P value
Period 6vs Period 3
0.24(0.09–0.52)
P = 0.0001
Period 6vs Period 4
0.22(0.09–0.47)
P < 0.0001
Period 6vs Period 5
0.29(0.11–0.66)
P = 0.001
Period 6vs Period 1comparable to Period 1 for the first time
0.59(0.21–1.62)
P = 0.27

Observational data: associations, not effects.

Original publication

Infectious complications associated with buttonhole cannulation of native arteriovenous fistulas: a 22-year follow-up. Nephrol Dial Transplant. Published 23 October 2023. doi:10.1093/ndt/gfad229

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.