Improvements in digital pathology equipment for renal biopsies: updating the standard model
Authors' conclusion
The present report describes the experience of a hub nephropathology center adopting next generation digital pathology tools for the routine assessment of renal biopsies, highlighting the need for a complementary approach towards a philosophy of interoperability.
Study context
- Population
- Renal biopsy slides scanned in a nephropathology hub
- Comparison
- Hybrid MIDI II scanner vs Aperio scanner
- Outcome
- Scanning performance, light microscopy (default and custom settings)
Methodological detailssingle hub nephropathology centre, comparative quality control check of whole slide images
- Single hub nephropathology centre
- Comparative quality control check of whole slide images
Main finding
As reported in the abstract
- No differences in number of out-of-focus slides per case (p = 0.75)
- MIDI II vs Aperio: P < 0.001
Further findings
| Outcome | P value |
|---|---|
| Scanning performance, immunofluorescenceLonger preparation time with the new scanner | P = 0.001 |
Scanning performance, immunofluorescence
- Comparable scanning times (p = 0.169) and final file size (p = 0.177)
Quality control of whole slide images
- Differences in 3 quality features related to white background and blurriness (p < 0.001)
Diagnostic concordance
- No major discordances in final diagnosis; minor disagreement
- 1 case (4%)
Original publication
Improvements in digital pathology equipment for renal biopsies: updating the standard model. J Nephrol. Published 14 February 2023. doi:10. 1007/ s40620-023-01568-1