Acute kidney injury

Impact of post-filter ionized calcium target range on circuit survival and citrate-related complications in pediatric continuous kidney replacement therapy

Pediatr NephrolPublished Retrospective cohort study

Authors' conclusion

Raising the target of post-filter ionized calcium from 0.25-0.35 to 0.30-0.40 mmol/L reduced citrate exposure and metabolic complications without compromising CS.

Study context

Population
Critically ill children receiving continuous veno-venous hemodiafiltration with pre-filter citrate anticoagulation at a tertiary pediatric ICU over 4 years154 circuits
Participants
87 children
Exposure
Low-target vs high-target post-filter ionized calcium in regional citrate anticoagulation (RCA)
  • Low-targetn = 42
  • High-targetn = 45reference
Outcome
Circuit survival
Methodological detailssingle tertiary PICU, Cox regression, linear mixed models, generalized estimating equations
  • Single tertiary PICU
  • Cox regression
  • Linear mixed models
  • Generalized estimating equations

Main finding

As reported in the abstract

Median circuit survival (CS)
  • Median circuit survival (CS) comparable between groups
  • Between Low-target and High-target: P = 0.76

Observational data: associations, not effects.

Secondary outcomes

Median citrate dose · higher with Low-target

P < 0.001

Citrate load · higher with Low-target

P = 0.03

Survival of clotted circuits · comparable between groups
P = 0.70
Circuit clotting rates · similar between groups
P = 0.70

Survival of clotted circuits

Survival of clotted circuits comparable between groups

Circuit clotting rates

Circuit clotting rates similar

Citrate dose and load over time (linear mixed models)

Persistently higher citrate dose and citrate load in the low-target group (all p < 0.001)

Safety

Hypocalcemia

P = 0.01

Metabolic alkalosis

P < 0.001

Citrate accumulation

P < 0.001

OutcomeORP value
HypocalcemiaGeneralized estimating equations1.47P = 0.01
Citrate accumulationGeneralized estimating equations1.93P < 0.001

Original publication

Impact of post-filter ionized calcium target range on circuit survival and citrate-related complications in pediatric continuous kidney replacement therapy. Pediatr Nephrol. Published 8 July 2026. doi:10.1007/s00467-026-07440-1

Composed by AI from the published abstract and checked against it. How Briefs are made →