Impact of post-filter ionized calcium target range on circuit survival and citrate-related complications in pediatric continuous kidney replacement therapy
Authors' conclusion
Raising the target of post-filter ionized calcium from 0.25-0.35 to 0.30-0.40 mmol/L reduced citrate exposure and metabolic complications without compromising CS.
Study context
- Population
- Critically ill children receiving continuous veno-venous hemodiafiltration with pre-filter citrate anticoagulation at a tertiary pediatric ICU over 4 years154 circuits
- Participants
- 87 children
- Exposure
- Low-target vs high-target post-filter ionized calcium in regional citrate anticoagulation (RCA)
- Low-targetn = 42
- High-targetn = 45reference
- Outcome
- Circuit survival
Methodological detailssingle tertiary PICU, Cox regression, linear mixed models, generalized estimating equations
- Single tertiary PICU
- Cox regression
- Linear mixed models
- Generalized estimating equations
Main finding
As reported in the abstract
Median circuit survival (CS)
- Median circuit survival (CS) comparable between groups
- Between Low-target and High-target: P = 0.76
Observational data: associations, not effects.
Secondary outcomes
Median citrate dose · higher with Low-target
P < 0.001
Citrate load · higher with Low-target
P = 0.03
- Survival of clotted circuits · comparable between groups
- P = 0.70
- Circuit clotting rates · similar between groups
- P = 0.70
Survival of clotted circuits
- Survival of clotted circuits comparable between groups
Circuit clotting rates
- Circuit clotting rates similar
Citrate dose and load over time (linear mixed models)
- Persistently higher citrate dose and citrate load in the low-target group (all p < 0.001)
Safety
Hypocalcemia
P = 0.01
Metabolic alkalosis
P < 0.001
Citrate accumulation
P < 0.001
| Outcome | OR | P value |
|---|---|---|
| HypocalcemiaGeneralized estimating equations | 1.47 | P = 0.01 |
| Citrate accumulationGeneralized estimating equations | 1.93 | P < 0.001 |
Original publication
Impact of post-filter ionized calcium target range on circuit survival and citrate-related complications in pediatric continuous kidney replacement therapy. Pediatr Nephrol. Published 8 July 2026. doi:10. 1007/ s00467-026-07440-1
Composed by AI from the published abstract and checked against it. How Briefs are made →