Impact of a continuous quality improvement program on contrast-induced nephropathy in outpatients with chronic kidney disease: an interrupted time-series study
Authors' conclusion
The multifaceted approach in the CIN-QI program may be associated with the decreased incidence of CIN and increased rates of prophylactic hydration and follow-up kidney function testing.
Study context
- Population
- Outpatients with chronic kidney disease (CKD) undergoing contrast-enhanced computed tomography (CT), 2006 to 2018
- Participants
- 95,594 outpatients
- Exposure
- CIN-QI program vs before the program
- Outcome
- Rates of prophylactic hydration and follow-up kidney function assessment, and incidence of CIN for eligible patients
Methodological detailsmulti-center, prospective
- Multi-center
- Prospective
Main finding
As reported in the abstract
Prophylactic hydration, follow-up kidney function testing and CIN
- Annual prophylactic hydration rate before the CIN-QI program
- 2.0% to 23.2%
- Annual prophylactic hydration rate during the CIN-QI program
- 59.2%-75.2%
- Increase in prophylactic hydration rate
- P < .001
- Annual rate of follow-up kidney function testing before the CIN-QI program
- 18.6%-25.8%
- Annual rate of follow-up kidney function testing after the CIN-QI program
- 34.1%-42.5%
- Improvement in follow-up kidney function testing
- P < .001
- Contrast-induced nephropathy (CIN) rate, level decline at the start of the CIN-QI program
- 10.0% (P = .002)
- CIN rate, trend decline
- 2.9%/year (P < .001)
Observational data: associations, not effects.
Further findings
Contrast-enhanced CT orders
- Trend in patients with advanced CKD, from −1.4%/year to
- −10.0%/year
- Positive level change in patients with advanced CKD (estimated glomerular filtration rate (eGFR) <45 mL/min/1.73 m²) at the start of the CIN-QI program
- Negative trend change across all patients after the CIN-QI program
Original publication
Impact of a continuous quality improvement program on contrast-induced nephropathy in outpatients with chronic kidney disease: an interrupted time-series study. Nephrol Dial Transplant. Published 13 September 2022. doi:10. 1093/ ndt/ gfac268
Composed by AI from the published abstract and checked against it. How Briefs are made →