Impact of continuous glucose monitoring on glycemic control and biochemical cardiovascular risk factors in kidney transplant recipients with type 1 diabetes
Authors' conclusion
Application of CGM technology in kidney graft recipients with T1D enabled good control of glucose levels and allowed for normalization of a number of biochemical risk factors for CVD. Pancreas transplantation remains the optimal procedure in achieving physiological blood glucose levels in T1D kidney recipients.
Study context
- Population
- Kidney transplant recipients with type 1 diabetes
- Participants
- 22 vs 22
- Exposure
- KTx recipients with T1D using continuous glucose monitoring (CGM) vs SPK recipients with T1D
- KTx CGMn = 22
- SPKn = 22reference
- Outcome
- Biochemical markers of glycemic control and CVD risk
- Follow-up
- 9-11 year
Methodological detailsgroups matched for age and diabetes duration at transplantation, age at study, sex, body mass index (BMI), total dialysis duration, dialysis modality, pretransplant cardiovascular disease (CVD) and kidney re-transplantation rates, long-term follow-up
- Groups matched for age and diabetes duration at transplantation, age at study, sex, BMI, total dialysis duration, dialysis modality, pretransplant CVD and kidney re-transplantation rates
- Long-term follow-up
Main finding
As reported in the abstract
Fasting plasma glucose
P < 0.01
Key notes
- Higher with KTx CGM
Observational data: associations, not effects.
Further findings
HbA1c · higher with KTx CGM
P < 0.001
LDL · lower with KTx CGM
P = 0.056
Serum creatinine · higher with KTx CGM
P < 0.01
| Outcome | KTx CGM | SPK | P value |
|---|---|---|---|
| TriglyceridesHigher with KTx CGM | 1.29 ± 0.45 mmol/L | 1.02 ± 0.39 mmo/L | P < 0.05 |
- Estimated glomerular filtration rates (eGFR) · lower with KTx CGM
- P < 0.01
- eGFR: printed values' order conflicts with the stated direction; values omitted
Total cholesterol and high-density lipoprotein (HDL)
- Total cholesterol (TC) and HDL did not differ between groups
Original publication
Impact of continuous glucose monitoring on glycemic control and biochemical cardiovascular risk factors in kidney transplant recipients with type 1 diabetes. Nephrol Dial Transplant. Published 3 August 2026. doi:10. 1093/ ndt/ gfag168
Composed by AI from the published abstract and checked against it. How Briefs are made →