Identification of Predictors of Tunneled Central Venous Catheter Dysfunction in Hemodialysis: A Multicenter Retrospective Cohort With Repeated‐Measure Sessions
Authors' conclusion
Tunneled central venous catheter dysfunction is a preventable complication when clinical, technical, and hemodynamic parameters are systematically monitored to identify risk factors and guide catheter management. Continuous session-based monitoring enables early detection and timely intervention. This comprehensive strategy, when combined with pharmacologic management, helps preserve vascular access and enhances treatment outcomes in hemodialysis patients.
Study context
- Population
- HD sessions performed in 2021 in 18 public hospitals in patients with tunneled CVC18 public hospitals
- Outcome
- Catheter dysfunction in the subsequent session, defined as blood flow < 300 mL/min with associated arterial or venous pressure changes
- Follow-up
- Subsequent session
Methodological detailsmulticenter, repeated measures, mixed-effects logistic regression with a random intercept for each patient, Unit of analysis: the index session
- Multicenter
- Repeated measures
- Mixed-effects logistic regression with a random intercept for each patient
- Unit of analysis: the index session
Main finding
As reported in the abstract
Predictors of catheter dysfunction
- Significant associations between catheter dysfunction and lower blood flow rates, elevated venous pressures, line inversion and catheter placement in the left internal jugular vein
- Protective factors: urokinase locking and post-dilution HDF
- Higher risk with interstitial nephropathies and unknown etiologies; prior vascular access reduced the risk of dysfunction
Original publication
Identification of Predictors of Tunneled Central Venous Catheter Dysfunction in Hemodialysis: A Multicenter Retrospective Cohort With Repeated‐Measure Sessions. Semin Dial. Published 28 April 2026. doi:10. 1111/ sdi. 70034
Composed by AI from the published abstract and checked against it. How Briefs are made →