Hemodialysis

Handheld ultrasound‐guided cannulation of difficult hemodialysis arteriovenous access: A randomized controlled trial

Hemodial IntPublished Randomised controlled trial

Authors' conclusion

Our study showed that US-guided cannulation increased renal nurses' confidence level in difficult cannulation and improved success rate. Larger scale studies are required to further assess the applications of handheld US in AVF cannulation, particularly in different clinical settings (e.g., chronic dialysis centers).

Study context

Population
HD patients with complex arteriovenous fistula (AVF) in a hospital-based dialysis unit10 renal nurses trained
Participants
50 patients
Comparison
Ultrasound (US)-guided vs conventional cannulation of complex AVF
Primary endpoint
Successful cannulation (only one cannulation attempt required)
Methodological detailssingle-center, January 2021 to January 2022
  • Single-center
  • January 2021 to January 2022

Primary result

As reported in the abstract

Success rate (only one cannulation attempt required)

P = 0.049

Further findings

OutcomeUS-guidedConventionalP value
Pain scoreLower with US-guided1.48 ± 0.732.13 ± 0.95P = 0.012
Nurses' confidence score · pre- vs posttrainingHigher posttrainingP = 0.014
  • Nurses' confidence score: Pretraining 26.6 ± 6.9
  • Nurses' confidence score: Posttraining 36.4 ± 3.0

Pre-cannulation assessment time and cannulation time

Comparable between the two groups

Original publication

Handheld ultrasound‐guided cannulation of difficult hemodialysis arteriovenous access: A randomized controlled trial. Hemodial Int. Published 25 October 2022. doi:10.1111/hdi.13050

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.