Glomerular disease

Glomerular basement membrane thickness estimation and stratification via active semi-supervised learning model

Am J NephrolPublished Diagnostic accuracy study

Authors' conclusion

The proposed pipeline obtained state-of-the-art performance in GBM segmentation, proving its robustness under image variations, such as magnification, contrast, and complex geometrical shapes. Automated measures could assist clinicians in standard clinical practice speeding up routine procedures with high diagnostic accuracy.

Study context

Population
Renal biopsies with normal, thin or thick glomerular basement membrane (GBM) on transmission electron microscopy (TEM) images42 renal biopsies
Comparison
Automated GBM segmentation and thickness estimation vs manual measurements and diagnostic records
Outcome
Automated GBM thickness estimation and stratification
Methodological detailsfully automated pipeline, active semi-supervised learning, convolutional neural network
  • Fully automated pipeline
  • Active semi-supervised learning
  • Convolutional neural network

Performance

As reported in the abstract

Correlation with manual measurements, Pearson's R2

0.85

Stratification into normal, thin, thick: Matthews correlation coefficient

0.63

Stratification into normal, thin, thick: accuracy

0.76

Original publication

Glomerular basement membrane thickness estimation and stratification via active semi-supervised learning model. Am J Nephrol. Published 15 April 2025. doi:10.1159/000542658

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.