Glomerular disease

External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis

J Am Soc NephrolPublished Diagnostic accuracy study

Authors' conclusion

An AIN diagnostic model retained discrimination in two validation cohorts but needed recalibration to account for local AIN prevalence. The model improved clinicians’ ability to predict AIN.

Study context

Population
Patients who underwent kidney biopsy at Johns Hopkins Hospital (JHH) and Yale University (2019–2023)
Participants
1,982 patients
Comparison
AIN diagnostic model in JHH and Yale validation cohorts vs development set
  • JHHn = 1,454
  • Yalen = 528
Outcome
Discrimination (AUC) and calibration of the model for biopsy-confirmed AIN
Methodological detailsexternal validation, two biopsy-based cohorts, intercept correction factor recalibration
  • External validation
  • Two biopsy-based cohorts
  • Intercept correction factor recalibration

Performance

As reported in the abstract

Discrimination for biopsy-confirmed AIN (AUC)
Test or modelAUC
Johns Hopkins HospitalJHH0.73 (95% CI 0.66 to 0.79)
Yale0.73 (95% CI 0.67 to 0.78)
Development set0.73 (95% CI 0.64 to 0.81)

AUC

Johns Hopkins HospitalJHH0.73 (95% CI 0.66 to 0.79)
Yale0.73 (95% CI 0.67 to 0.78)
Development set0.73 (95% CI 0.64 to 0.81)

Further findings

Proportion of biopsies with AIN

Clinicians' prebiopsy suspicion for AIN plus model

Model increased AUC of clinicians' prebiopsy suspicion by 0.10 to
0.77 (95% CI 0.71 to 0.82)

Original publication

External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis. J Am Soc Nephrol. Published 5 November 2024. doi:10.1681/asn.0000000556

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.