Elimination and penetration of amikacin into urine in patients with decreased glomerular filtration rate
Authors' conclusion
Systemic administration of amikacin monotherapy in patients treated by dialysis is questionable as the concentrations of amikacin in their urine are often below the threshold of effectivity. Amikacin plasma concentrations are not a major determinant of amikacin concentration in urine, therefore pulse dosing is neither necessary nor safe in patients treated by dialysis, and may cause undesirable toxicity.
Study context
- Population
- Patients with different levels of glomerular filtration decline, including patients treated by dialysis, receiving amikacin40 males
- Participants
- 70 patients
- Exposure
- Estimated GFR (eGFR) <30 mL/min vs eGFR >30 mL/min
- Outcome
- Amikacin penetration into urine (urinary concentration)
Methodological detailsBactericidal efficacy of amikacin in urine samples evaluated
- Bactericidal efficacy of amikacin in urine samples evaluated
Main finding
As reported in the abstract
| Group | Value | Maximal concentration | Minimal together with maximal concentrations |
|---|---|---|---|
| eGFR <30 mL/min | median 89.75 mg/L | 200.5 mg/L | 126.0 mg/L |
| eGFR >30 mL/min | median 186.0 mg/L | 830.0 mg/L | 408.0 mg/L |
Value
Maximal concentration
Minimal together with maximal concentrations
- eGFR <30 mL/min vs eGFR >30 mL/min: P < 0.0001 — minimal concentrations; also P < .0001 for maximal and for minimal together with maximal
Key notes
- Value is minimal concentration
- Significantly lower with eGFR <30 mL/min
Observational data: associations, not effects.
Further findings
Amikacin eliminated in first 10-13 h vs eGFR · first 10-13 h after dose
- Amount eliminated dependent on eGFR, r2
- 0.6144, P < .0001
Urinary concentration in dialysis patients
- Indirectly proportional to urine pH
Plasma vs urinary amikacin
- Plasma concentrations did not correlate with urinary levels in either glomerular filtration rate (GFR) category
Critical urinary concentration for efficacy in dialysis patients
- Critical urinary concentration
- 100 mg/L
- Dialysis patients not reaching this level during treatment
- 4 out of 11
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →