Effects of Extracorporeal Blood Flow Rates on Patient Tolerance for LIXELLE<sup>®</sup> Treatment during Outpatient Hemodialysis
Authors' conclusion
LIXELLE plus HD across all column sizes was safe and well tolerated at blood flow rates up to 450 mL/min. Extent of B2M removal corresponded to column size-blood flow rate combinations. This EFS provides a risk profile to guide further studies of LIXELLE in ESKD patients at US-standard blood flow rates.
Study context
- Population
- End-stage kidney disease (ESKD) patients (40–75 years old) on thrice weekly outpatient hemodialysis (HD)9 completed all combinations
- Participants
- 10 patients
- Exposure
- LIXELLE plus HD at blood flow rate 250 mL/min, then up to 450 mL/min, with three column sizes in sequence
- LIXELLE plus HDn = 10
- Outcome
- Tolerance and safety of LIXELLE treatment during HD at blood flow rates up to 450 mL/min
Methodological detailsprospective, open-label, non-randomized, single-arm
- Prospective
- Open-label
- Non-randomized
- Single-arm
Main finding
As reported in the abstract
Tolerance (IDH)
Historic intradialytic hypotension (IDH) rate, events/HD session/patient
0.42
Patients completing all combinations without IDH events
9
Treatment IDH rate, events/HD session/patient
0.56
Observational data: associations, not effects.
Further findings
- B2M reduction ratios and removal of select proteins (<40 kDa) increased with escalating column size and blood flow rate
Safety
- Treatment-emergent serious adverse events
- 0
- No significant changes in red blood cell, platelet, or complement indices except haptoglobin
Original publication
Effects of Extracorporeal Blood Flow Rates on Patient Tolerance for LIXELLE<sup>®</sup> Treatment during Outpatient Hemodialysis. Blood Purif. Published 16 January 2024. doi:10. 1159/ 000536075
Composed by AI from the published abstract and checked against it. How Briefs are made →