Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis

Pediatr NephrolPublished Cross-sectional study

Authors' conclusion

A total of 94.1% of BIA parameters exhibited excellent correlations between D + and D- measurements, especially patients older than 10 years. We recommend that BIA measurements be collected from children regardless of the presence of peritoneal dialysate.

Study context

Population
CKD stage 5 patients aged 3 to 18 years receiving PD50 paired bioelectrical impedance analysis (BIA) measurements
Participants
18 participants
Exposure
BIA with peritoneal dialysate present vs absent
Outcome
Agreement of BIA body composition values between D + and D- measurements (ICC)
Methodological detailspaired measurements, multifrequency BIA
  • Paired measurements
  • Multifrequency BIA

Main finding

As reported in the abstract

BIA parameters with excellent correlations between D + and D-

16 of 17

94.1%

Intraclass correlation coefficient (ICC) values

0.954, 0.998

Observational data: associations, not effects.

Further findings

Between D + and D-

OutcomeEstimate
Fluid status (extracellular water, edema index, overhydration)Extracellular water · higher with D + · trend of increased fluid status in D + measurementsmean difference 0.5 L (95% CI 0.4–0.6)
Fluid status (extracellular water, edema index, overhydration)Edema index · higher with D + · trend of increased fluid status in D + measurementsmean difference 0.002 (95% CI 0.001–0.002)
Fluid status (extracellular water, edema index, overhydration)Overhydration · higher with D + · trend of increased fluid status in D + measurementsmean difference 0.1 L (95% CI 0.1–0.2)
Soft lean mass and fat-free massSoft lean mass · higher with D +mean difference 1.4 kg (95% CI 1.2–1.6)
Soft lean mass and fat-free massFat-free mass · higher with D +mean difference 1.6 kg (95% CI 1.4–1.8)

Agreement by age

Patients older than 10 years had a stronger correlation between D + and D- than younger patients

Original publication

Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis. Pediatr Nephrol. Published 16 November 2023. doi:10.1007/s00467-023-06219-y

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.